Interrupted ‘Figure-of-X’ versus continuous suturing technique for abdominal wall closure in colorectal laparotomies: A comparative study on the incidence of burst abdomen
- Akbar Niazi Teaching Hospital/IMDC, Islamabad
Abstract
Background: After colorectal laparotomies, burst abdomen is still a serious complication that increases morbidity, necessitates reoperation, and prolongs hospital stays. There is ongoing discussion regarding the best fascial closure method for high-risk colorectal surgery.
Objective: To compare continuous and interrupted Figure-of-X suturing methods for abdominal wall closure in colorectal laparotomies, with an emphasis on postoperative wound-related complications and the frequency of burst abdomen.
Methods: This prospective, single-center, comparative study was conducted in the Department of General Surgery, Akbar Niazi Teaching Hospital, Islamabad, Pakistan, from November 2025 to February 2026. Total 40 patients undergoing colorectal cancer laparotomy were included in the study; they were divided into two groups: Group A (Interrupted Figure-of-X, n = 20) and Group B (Continuous suturing, n = 20). The main outcome was an abdominal rupture within 30 days. Surgical site infection (SSI), seroma, hematoma, length of hospital stay, and reoperation were examples of secondary outcomes.
Results: Burst abdomen occurred in 5 (12.5%) patients: 1 (5%) in Group A and 4 (20%) in Group B (RR=4.0; 95% CI: 0.5–31.2; p=0.15). SSI was observed in 8 (20%) patients (3 [15%] vs 5 [25%]; p=0.44). Seroma occurred in 6 (15%) patients (2 [10%] vs 4 [20%]), and hematoma in 3 (7.5%) patients (1 [5%] vs 2 [10%]). Reoperation was needed in 3 (7.5%) patients. The mean hospital stay was 8.6±2.7 days (7.9±2.3 vs 9.3±2.9 days; p=0.09). 4 out of 5 patients with a burst abdomen had hypoalbuminemia, and dehiscence cases were more likely to require emergency surgery.
Conclusion: Although the differences were not statistically significant, interrupted Figure-of-X closure was associated with a lower incidence of burst abdomen and wound complications than continuous suturing.
Metrics
Keywords
License
Copyright (c) 2026 Munazzah Aziz, Rizwan Aziz, Sohaib Haider, Atiq ur Rehman, Taimoor Ahmed, Tayyaba Ismail

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.